SUPER STRUCTURE WALL

Providing and pouring reinforced cement concrete of specified with a 28-day compressive strength of 28MPa for all RCC works, including necessary formwork, centering, shuttering, mixing, transporting, laying, vibrating, levelling, curing, removal of shutters, reinforcement Grade 40 for all sizes 12mm diameter and below, and Grade 60 for all sizes.

02

SITE WORKS

Site clearing and demolition and removal of portions of existing structures, existing stairs that may be affected by the improvement works and hauling-out of unusable demolished materials and all other necessary site works.

03

EARTHWORKS

Excavation with required depth in all classes of soil keeping the good earth near the site at suitable location for backfilling the sides of foundations, footings etc. including breaking clods, necessary levelling, watering and manually consolidating

05

WALL FINISHING WORK

Plastering for walls on two layers, first layer of 2.5 cm of gypsum and second layer not less than 2 mm of plaster prepared to accept paint finish.

07

CEILING FINISHING WORK

Provide materials, manpower and install 60X60 Gypsum panel/Metal panel/acoustic panel suspended ceiling with suspension metal structure..

01

BACKFILLING

under the proposed foundation using hard course sub-base backfill to the elevation of the bottom of the found -ation and under the floor slab and the walkways with clean granular soil from the excavation and Supplying and filling with required backfilling under foundation, floors, cable trenches etc.

04

BRICK MASONRY WORKS

Providing and constructing brick masonry using good quality bricks of class designation 50 (compressive strength not less than 50 kg/cm2), in cement mortar for walls (brick of size not less than 21 cm), including soaking bricks in water, scaffolding, curing, all joint reinforcement and ties to concrete, etc. In footing,

06

MECHANICAL WORKS

Supply, install of package unit 100% full fresh air, cooling capacity 15 ton and design temperature of 46 degrees Celsius as well as a condensing temperature of 54 degrees celsius, supply air (3200 cfm) with external static pressure (300) Pa, entering air temperature (46C) and leaving air temperature (16C), electric heater (21) kw by heater element, package unit casing air side double skin with thermal insulation and contain two separate cycle, with hot gas bypass compressor type Hermetic scroll works with refrigerant R407 C or R410 A,

08

FLOOR FINISHING WORK

Supply and laying unglazed ceramic floor tiles including cement and sand bed, grouting, point up joints
& cleaning.

MECHANICAL WORKS

Supplying, installing, testing & commissioning HVAC system including electrical wiring, piping, conduits, switches and warranty.

02

MISCELLANEOUS WORKS

Supply Material, installation, testing & commissioning of circular water Fountain’s work includes provision of civil & mechanical design and shop drawings also includes all the civil works (excavating, compacting, reinforcement, form works

03

IT WORKS

Supply and Install Heavy Duty Tray Cable, Hot Dip Galvanized, Steel along with all accessories including coupling, bends and screws for fitment on ceiling for the purpose of running ethernet cable.

05

PRECAST CONCRETE WORKS

Supply all kind of T-walls, Corners, boundary walls, precast piles and all other concrete walls.

01

ELECTRICAL WORKS

Supplying, installation and commissioning socket outlet power supply, switches, lighting pole, lighting system, multi-core cables of stranded copper conductors are insulated with XPLE compound assembled together armored with steel wires and covered with overall jacket of XPLE compound with wires and all accessories..etc to complete the installation.

04

STEEL STRUCTURAL WORKS

Erection main steel structure frames for Warehouses/workshops including Mezzanine roll up door installation, fans, skylights and all other works.

06

TELECOM OPERATORS

Supply, install of package unit 100% full fresh air, cooling capacity 15 ton and design temperature of 46 degrees Celsius as well as a condensing temperature of 54 degrees celsius, supply air (3200 cfm) with external static pressure (300) Pa, entering air temperature (46C) and leaving air temperature (16C), electric heater (21) kw by heater element, package unit casing air side double skin with thermal insulation and contain two separate cycle, with hot gas bypass compressor type Hermetic scroll works with refrigerant R407 C or R410 A,

LAND SCAPING

Landscape means the natural and physical attributes of land together with air and water which change over time, and which is made known by people’s evolving perceptions and associations such as beliefs, uses, values and relationships.